{"id":4368,"date":"2021-09-24T01:46:00","date_gmt":"2021-09-24T01:46:00","guid":{"rendered":"https:\/\/www.vistaar.ai\/?p=4368"},"modified":"2025-12-03T04:17:09","modified_gmt":"2025-12-03T04:17:09","slug":"infusion-pumps-safety-assurance","status":"publish","type":"post","link":"https:\/\/stage-websites.ddismart.com\/vistaar\/blog\/infusion-pumps-safety-assurance\/","title":{"rendered":"Infusion Pumps Safety Assurance"},"content":{"rendered":"\n<p class=\"has-black-color has-text-color has-link-color wp-elements-8dbabf4cd557b90ac368e314c8bd0d88 wp-block-paragraph\">The FDA\u2019s guidance, \u201cInfusion Pumps Total Product Life Cycle,\u201d provides recommendations for preparing premarket submissions for infusion pumps and identifies device features that manufacturers should address throughout the full product life cycle. This guidance applies to Class II devices regulated under 21 CFR 880.5725, including the product codes listed below.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"color:#000\"><tbody style=\"color:#000\"><tr><td><strong>Product code<\/strong><\/td><td><strong>Description<\/strong><\/td><\/tr><tr><td>FRN<\/td><td>Infusion pump<\/td><\/tr><tr><td>MEA<\/td><td>Patient controlled analgesia (PCA) infusion pump<\/td><\/tr><tr><td>MEB<\/td><td>Elastomeric infusion pump<\/td><\/tr><tr><td>LZG<\/td><td>Insulin infusion pump<\/td><\/tr><tr><td>OPP<\/td><td>Insulin bolus infusion pump<\/td><\/tr><tr><td>LZH<\/td><td>Enteral infusion pump<\/td><\/tr><tr><td>MRZ<\/td><td>Infusion pump accessories<\/td><\/tr><tr><td>PHC<\/td><td>Infusion Safety Management Software<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading has-black-color has-text-color has-link-color wp-elements-bcd119610d80bd9af74b1809047fc83d\">Safety Assurance Case&nbsp;<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Infusion pump 510(k) submissions often involve software, design, material, or performance modifications compared to the predicate device. FDA expects many new or modified devices to have different technological characteristics from predicates, even when the intended use remains unchanged.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Under Section 513(i) of the FD&amp;C Act, substantial equivalence is determined based on whether the new or modified device is as safe and effective as the legally marketed predicate and does not raise different safety or effectiveness concerns.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>A. General Considerations for Safety Case Development\u00a0<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A safety assurance case consists of three elements:\u00a0<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Claim \u2013<\/strong> A statement describing a property or capability of the system or subsystem.\u00a0<\/li>\n\n\n\n<li><strong>Argument \u2013 <\/strong>A rationale linking the evidence to the claim.\u00a0<\/li>\n\n\n\n<li><strong>Evidence \u2013 <\/strong>Supporting information validating the argument.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading has-black-color has-text-color has-link-color wp-elements-886bf021d3a0b43a325b34d3daccde29\"><strong>B. Hazard Analysis<\/strong><\/h3>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-ed4dd8d8aec2ce7b6dc1df1e4e003473 wp-block-paragraph\">The objective of the hazard analysis is to identify hazards and potential causes of the hazards.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"color:#000\"><tbody style=\"color:#000\"><tr><td>Infusion Pump System Hazards<\/td><td>System Hazard Definitions<\/td><\/tr><tr><td>Infusion Delivery Error<\/td><td>Intended medication selected and delivery attempted, but failure to deliver within the right time, dose, volume, patient, or anatomical or physiologic site specifications. This can include over-delivery, under-delivery or delay in delivery situations.<\/td><\/tr><tr><td>Incorrect Therapy<\/td><td>Failure to select or deliver the intended medication because the wrong substance was selected for delivery.<\/td><\/tr><tr><td>Biological\/Chemical Contamination<\/td><td>Unintended contact with biological or chemical substance, or unintended patient or provider physiologic response to intended biological or chemical substance.<\/td><\/tr><tr><td>Traumatic Injury<\/td><td>Burns, cuts, abrasions, air embolisms, electric shock, etc.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading has-black-color has-text-color has-link-color wp-elements-f7db3a384c51bc991eeded78bc852ba2\"><strong>\u00a0\u00a0<\/strong>C. Performance Testing&nbsp;<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Performance testing must incorporate statistical considerations\u2014including hypotheses, sample size, power, controls, endpoints, and bias minimization. A 510(k) submission should include:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>The design requirement being verified and its importance to device function.\u00a0<\/li>\n\n\n\n<li>Description of the tested unit and its relation to the finished device.\u00a0<\/li>\n\n\n\n<li>Justification for using prototypes or production\u2011equivalent units.\u00a0<\/li>\n\n\n\n<li>Explicit acceptance criteria.\u00a0<\/li>\n\n\n\n<li>Detailed verification methods, including test apparatus descriptions when relevant.\u00a0<\/li>\n\n\n\n<li>Explanation of how testing simulates clinical use, when applicable.\u00a0<\/li>\n\n\n\n<li>Test results.\u00a0<\/li>\n\n\n\n<li>Analysis of those results.\u00a0<\/li>\n\n\n\n<li>Clear conclusions based on the findings.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>D. Labeling\u00a0<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>In addition to the requirements in 21 CFR 801.109, labeling should include:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Indications for use\u00a0<\/li>\n\n\n\n<li>Cleaning and disinfection instructions for reusable pumps\u00a0<\/li>\n\n\n\n<li>Alarm limits and ranges\u00a0<\/li>\n\n\n\n<li>Default settings\u00a0<\/li>\n\n\n\n<li>Full user interface representation\u00a0<\/li>\n\n\n\n<li>Compatible or dedicated administration sets\u00a0<\/li>\n\n\n\n<li>Reservoir capacity, flow rate options, infusion profiles, and residual volume\u00a0<\/li>\n\n\n\n<li>Factors affecting flow accuracy (temperature, viscosity, pressure, etc.)\u00a0<\/li>\n\n\n\n<li>Accuracy specifications across flow rates and bolus volumes\u00a0<\/li>\n\n\n\n<li>Bolus delivery rate\u00a0<\/li>\n\n\n\n<li>Description of permissible fluids\u00a0<\/li>\n\n\n\n<li>Complete operating instructions\u00a0<\/li>\n\n\n\n<li>Methods for verifying calibration\u00a0<\/li>\n\n\n\n<li>Alarm and message descriptions with recommended user actions\u00a0<\/li>\n\n\n\n<li>Warnings related to diagnostic procedures\u00a0<\/li>\n\n\n\n<li>EMC-related information with reference to standards (e.g., IEC 60601\u20111\u20112)\u00a0<\/li>\n\n\n\n<li>Details on RF wireless capabilities (if applicable)\u00a0<\/li>\n\n\n\n<li>Information for users with disabilities, when relevant<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>E. Alarms\u00a0<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Alarms must be clearly communicated to users. FDA recommends compliance with IEC 60601\u20111\u20118 for medical alarm systems. Manufacturers should assess risks associated with false alarms and missed alarms.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>F. Safety Control Mechanisms\u00a0<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Infusion pumps may include safety features intended to detect or prevent hazardous situations, such as:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Power\u2011on self\u2011tests\u00a0<\/li>\n\n\n\n<li>Battery functionality tests\u00a0<\/li>\n\n\n\n<li>Stuck key evaluations\u00a0<\/li>\n\n\n\n<li>Audible tone tests\u00a0<\/li>\n\n\n\n<li>Pump mechanism failure checks\u00a0<\/li>\n\n\n\n<li>Watchdog timer tests\u00a0<\/li>\n\n\n\n<li>System integrity checks (CPU, ROM\/RAM CRC tests)\u00a0<\/li>\n\n\n\n<li>Air\u2011in\u2011line detection sensors\u00a0<\/li>\n\n\n\n<li>Environmental sensors\u00a0<\/li>\n\n\n\n<li>Sensor functionality checks\u00a0<\/li>\n\n\n\n<li>Dose error reduction features\u00a0attached to the pump, if any; and 11. Dose error reduction checks.<\/li>\n<\/ol>\n\n\n<div style=\"color:#00bab9;font-size:16px\" class=\"taxonomy-post_tag has-link-color wp-elements-927c70617f5f183ae903ddc7892f010b wp-block-post-terms has-text-color\"><span class=\"wp-block-post-terms__prefix\"><mark style=\"background-color:#ffffff\" class=\"has-inline-color has-black-color\"><strong>Tags:<\/strong> <\/mark><\/span><a href=\"https:\/\/stage-websites.ddismart.com\/vistaar\/tag\/elastomeric-infusion-pump\/\" rel=\"tag\">Elastomeric infusion pump<\/a><span class=\"wp-block-post-terms__separator\">, <\/span><a href=\"https:\/\/stage-websites.ddismart.com\/vistaar\/tag\/enteral-infusion-pump\/\" rel=\"tag\">Enteral infusion pump<\/a><span class=\"wp-block-post-terms__separator\">, <\/span><a href=\"https:\/\/stage-websites.ddismart.com\/vistaar\/tag\/infusion-pump\/\" rel=\"tag\">Infusion pump<\/a><span class=\"wp-block-post-terms__separator\">, <\/span><a href=\"https:\/\/stage-websites.ddismart.com\/vistaar\/tag\/infusion-pump-accessories\/\" rel=\"tag\">Infusion pump accessories<\/a><span class=\"wp-block-post-terms__separator\">, <\/span><a href=\"https:\/\/stage-websites.ddismart.com\/vistaar\/tag\/infusion-safety-management-software\/\" rel=\"tag\">Infusion Safety Management Software<\/a><span class=\"wp-block-post-terms__separator\">, <\/span><a href=\"https:\/\/stage-websites.ddismart.com\/vistaar\/tag\/insulin-bolus-infusion-pump\/\" rel=\"tag\">Insulin bolus infusion pump<\/a><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The FDA\u2019s guidance, \u201cInfusion Pumps Total Product Life Cycle,\u201d provides recommendations for preparing premarket submissions for infusion pumps and identifies device features that manufacturers should address throughout the full product life cycle. This guidance applies to Class II devices regulated under 21 CFR 880.5725, including the product codes listed below. Product code Description FRN Infusion [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1885,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[647],"tags":[452,449,448,450,453,451],"class_list":["post-4368","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-standards","tag-elastomeric-infusion-pump","tag-enteral-infusion-pump","tag-infusion-pump","tag-infusion-pump-accessories","tag-infusion-safety-management-software","tag-insulin-bolus-infusion-pump"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\r\n<title>Infusion Pumps Safety Assurance<\/title>\r\n<meta name=\"description\" content=\"The US Food and Drug Administration (FDA)\u2019s guidance, entitled Infusion Pumps Total Product Life Cycle provides assistance to the industry in preparing premarket submissions for infusion pumps and to identify device features that manufacturers should address throughout the total product life cycle.\" \/>\r\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\r\n<link rel=\"canonical\" href=\"https:\/\/stage-websites.ddismart.com\/vistaar\/blog\/infusion-pumps-safety-assurance\/\" \/>\r\n<meta property=\"og:locale\" content=\"en_US\" \/>\r\n<meta property=\"og:type\" content=\"article\" \/>\r\n<meta property=\"og:title\" content=\"Infusion Pumps Safety Assurance\" \/>\r\n<meta property=\"og:description\" content=\"The US Food and Drug Administration (FDA)\u2019s guidance, entitled Infusion Pumps Total Product Life Cycle provides assistance to the industry in preparing premarket submissions for infusion pumps and to identify device features that manufacturers should address throughout the total product life cycle.\" \/>\r\n<meta property=\"og:url\" content=\"https:\/\/stage-websites.ddismart.com\/vistaar\/blog\/infusion-pumps-safety-assurance\/\" \/>\r\n<meta property=\"og:site_name\" content=\"Vistaar\" \/>\r\n<meta property=\"article:published_time\" content=\"2021-09-24T01:46:00+00:00\" \/>\r\n<meta property=\"article:modified_time\" content=\"2025-12-03T04:17:09+00:00\" \/>\r\n<meta property=\"og:image\" content=\"https:\/\/stage-websites.ddismart.com\/vistaar\/wp-content\/uploads\/2024\/01\/Standards-min.jpg\" \/>\r\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\r\n\t<meta property=\"og:image:height\" content=\"555\" \/>\r\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\r\n<meta name=\"author\" content=\"admin\" \/>\r\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\r\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\r\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/blog\\\/infusion-pumps-safety-assurance\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/blog\\\/infusion-pumps-safety-assurance\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/#\\\/schema\\\/person\\\/d62b304dd6b8cc3c3b5f77783874af43\"},\"headline\":\"Infusion Pumps Safety Assurance\",\"datePublished\":\"2021-09-24T01:46:00+00:00\",\"dateModified\":\"2025-12-03T04:17:09+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/blog\\\/infusion-pumps-safety-assurance\\\/\"},\"wordCount\":634,\"image\":{\"@id\":\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/blog\\\/infusion-pumps-safety-assurance\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/Standards-min.jpg\",\"keywords\":[\"Elastomeric infusion pump\",\"Enteral infusion pump\",\"Infusion pump\",\"Infusion pump accessories\",\"Infusion Safety Management Software\",\"Insulin bolus infusion pump\"],\"articleSection\":[\"Standards\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/blog\\\/infusion-pumps-safety-assurance\\\/\",\"url\":\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/blog\\\/infusion-pumps-safety-assurance\\\/\",\"name\":\"Infusion Pumps Safety Assurance\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/blog\\\/infusion-pumps-safety-assurance\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/blog\\\/infusion-pumps-safety-assurance\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/Standards-min.jpg\",\"datePublished\":\"2021-09-24T01:46:00+00:00\",\"dateModified\":\"2025-12-03T04:17:09+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/#\\\/schema\\\/person\\\/d62b304dd6b8cc3c3b5f77783874af43\"},\"description\":\"The US Food and Drug Administration (FDA)\u2019s guidance, entitled Infusion Pumps Total Product Life Cycle provides assistance to the industry in preparing premarket submissions for infusion pumps and to identify device features that manufacturers should address throughout the total product life cycle.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/blog\\\/infusion-pumps-safety-assurance\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/blog\\\/infusion-pumps-safety-assurance\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/blog\\\/infusion-pumps-safety-assurance\\\/#primaryimage\",\"url\":\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/Standards-min.jpg\",\"contentUrl\":\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/Standards-min.jpg\",\"width\":1200,\"height\":555,\"caption\":\"Standards\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/blog\\\/infusion-pumps-safety-assurance\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Infusion Pumps Safety Assurance\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/#website\",\"url\":\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/\",\"name\":\"Vistaar\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/#\\\/schema\\\/person\\\/d62b304dd6b8cc3c3b5f77783874af43\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0d089543c02b6aad11bd03612ee5efc6ddd700450a82976e93b20516f42f6cf4?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0d089543c02b6aad11bd03612ee5efc6ddd700450a82976e93b20516f42f6cf4?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0d089543c02b6aad11bd03612ee5efc6ddd700450a82976e93b20516f42f6cf4?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"https:\\\/\\\/www.vistaar.ai\"],\"url\":\"https:\\\/\\\/stage-websites.ddismart.com\\\/vistaar\\\/author\\\/admin\\\/\"}]}<\/script>\r\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Infusion Pumps Safety Assurance","description":"The US Food and Drug Administration (FDA)\u2019s guidance, entitled Infusion Pumps Total Product Life Cycle provides assistance to the industry in preparing premarket submissions for infusion pumps and to identify device features that manufacturers should address throughout the total product life cycle.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/stage-websites.ddismart.com\/vistaar\/blog\/infusion-pumps-safety-assurance\/","og_locale":"en_US","og_type":"article","og_title":"Infusion Pumps Safety Assurance","og_description":"The US Food and Drug Administration (FDA)\u2019s guidance, entitled Infusion Pumps Total Product Life Cycle provides assistance to the industry in preparing premarket submissions for infusion pumps and to identify device features that manufacturers should address throughout the total product life cycle.","og_url":"https:\/\/stage-websites.ddismart.com\/vistaar\/blog\/infusion-pumps-safety-assurance\/","og_site_name":"Vistaar","article_published_time":"2021-09-24T01:46:00+00:00","article_modified_time":"2025-12-03T04:17:09+00:00","og_image":[{"width":1200,"height":555,"url":"https:\/\/stage-websites.ddismart.com\/vistaar\/wp-content\/uploads\/2024\/01\/Standards-min.jpg","type":"image\/jpeg"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":false,"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/stage-websites.ddismart.com\/vistaar\/blog\/infusion-pumps-safety-assurance\/#article","isPartOf":{"@id":"https:\/\/stage-websites.ddismart.com\/vistaar\/blog\/infusion-pumps-safety-assurance\/"},"author":{"name":"admin","@id":"https:\/\/stage-websites.ddismart.com\/vistaar\/#\/schema\/person\/d62b304dd6b8cc3c3b5f77783874af43"},"headline":"Infusion Pumps Safety Assurance","datePublished":"2021-09-24T01:46:00+00:00","dateModified":"2025-12-03T04:17:09+00:00","mainEntityOfPage":{"@id":"https:\/\/stage-websites.ddismart.com\/vistaar\/blog\/infusion-pumps-safety-assurance\/"},"wordCount":634,"image":{"@id":"https:\/\/stage-websites.ddismart.com\/vistaar\/blog\/infusion-pumps-safety-assurance\/#primaryimage"},"thumbnailUrl":"https:\/\/stage-websites.ddismart.com\/vistaar\/wp-content\/uploads\/2024\/01\/Standards-min.jpg","keywords":["Elastomeric infusion pump","Enteral infusion pump","Infusion pump","Infusion pump accessories","Infusion Safety Management Software","Insulin bolus infusion pump"],"articleSection":["Standards"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/stage-websites.ddismart.com\/vistaar\/blog\/infusion-pumps-safety-assurance\/","url":"https:\/\/stage-websites.ddismart.com\/vistaar\/blog\/infusion-pumps-safety-assurance\/","name":"Infusion Pumps Safety Assurance","isPartOf":{"@id":"https:\/\/stage-websites.ddismart.com\/vistaar\/#website"},"primaryImageOfPage":{"@id":"https:\/\/stage-websites.ddismart.com\/vistaar\/blog\/infusion-pumps-safety-assurance\/#primaryimage"},"image":{"@id":"https:\/\/stage-websites.ddismart.com\/vistaar\/blog\/infusion-pumps-safety-assurance\/#primaryimage"},"thumbnailUrl":"https:\/\/stage-websites.ddismart.com\/vistaar\/wp-content\/uploads\/2024\/01\/Standards-min.jpg","datePublished":"2021-09-24T01:46:00+00:00","dateModified":"2025-12-03T04:17:09+00:00","author":{"@id":"https:\/\/stage-websites.ddismart.com\/vistaar\/#\/schema\/person\/d62b304dd6b8cc3c3b5f77783874af43"},"description":"The US Food and Drug Administration (FDA)\u2019s guidance, entitled Infusion Pumps Total Product Life Cycle provides assistance to the industry in preparing premarket submissions for infusion pumps and to identify device features that manufacturers should address throughout the total product life cycle.","breadcrumb":{"@id":"https:\/\/stage-websites.ddismart.com\/vistaar\/blog\/infusion-pumps-safety-assurance\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/stage-websites.ddismart.com\/vistaar\/blog\/infusion-pumps-safety-assurance\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/stage-websites.ddismart.com\/vistaar\/blog\/infusion-pumps-safety-assurance\/#primaryimage","url":"https:\/\/stage-websites.ddismart.com\/vistaar\/wp-content\/uploads\/2024\/01\/Standards-min.jpg","contentUrl":"https:\/\/stage-websites.ddismart.com\/vistaar\/wp-content\/uploads\/2024\/01\/Standards-min.jpg","width":1200,"height":555,"caption":"Standards"},{"@type":"BreadcrumbList","@id":"https:\/\/stage-websites.ddismart.com\/vistaar\/blog\/infusion-pumps-safety-assurance\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/stage-websites.ddismart.com\/vistaar\/"},{"@type":"ListItem","position":2,"name":"Infusion Pumps Safety Assurance"}]},{"@type":"WebSite","@id":"https:\/\/stage-websites.ddismart.com\/vistaar\/#website","url":"https:\/\/stage-websites.ddismart.com\/vistaar\/","name":"Vistaar","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/stage-websites.ddismart.com\/vistaar\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/stage-websites.ddismart.com\/vistaar\/#\/schema\/person\/d62b304dd6b8cc3c3b5f77783874af43","name":"admin","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/0d089543c02b6aad11bd03612ee5efc6ddd700450a82976e93b20516f42f6cf4?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/0d089543c02b6aad11bd03612ee5efc6ddd700450a82976e93b20516f42f6cf4?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/0d089543c02b6aad11bd03612ee5efc6ddd700450a82976e93b20516f42f6cf4?s=96&d=mm&r=g","caption":"admin"},"sameAs":["https:\/\/www.vistaar.ai"],"url":"https:\/\/stage-websites.ddismart.com\/vistaar\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/stage-websites.ddismart.com\/vistaar\/wp-json\/wp\/v2\/posts\/4368","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/stage-websites.ddismart.com\/vistaar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/stage-websites.ddismart.com\/vistaar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/stage-websites.ddismart.com\/vistaar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/stage-websites.ddismart.com\/vistaar\/wp-json\/wp\/v2\/comments?post=4368"}],"version-history":[{"count":4,"href":"https:\/\/stage-websites.ddismart.com\/vistaar\/wp-json\/wp\/v2\/posts\/4368\/revisions"}],"predecessor-version":[{"id":6845,"href":"https:\/\/stage-websites.ddismart.com\/vistaar\/wp-json\/wp\/v2\/posts\/4368\/revisions\/6845"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/stage-websites.ddismart.com\/vistaar\/wp-json\/wp\/v2\/media\/1885"}],"wp:attachment":[{"href":"https:\/\/stage-websites.ddismart.com\/vistaar\/wp-json\/wp\/v2\/media?parent=4368"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/stage-websites.ddismart.com\/vistaar\/wp-json\/wp\/v2\/categories?post=4368"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/stage-websites.ddismart.com\/vistaar\/wp-json\/wp\/v2\/tags?post=4368"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}